Impact Testing

Free Falling Dart Impact Tester

Free Falling Dart Impact Tester
Product Details:
  • Standard: ASTM D1709
  • Test Method: A & B

FDI-01 Free Falling Dart Impact Tester is applicable in the impact result and energy measurement of the falling dart from a certain height against plastic films and sheets, which would result in 50% tested specimen failure.

CHARACTERISTICS

Windows menu interface and touch screen

2 test methods of A & B

Multi-unit result display

RS232 port and micro printer

STANDARDS

The Falling Dart Impact Tester / Drop Dart Impact Tester conforms to ASTM D1709

TECHNCIAL SPECIFICATIONS
Test MethodMethod A or Method B is optional
Test RangeMethod A: 50~2000 g
Method B: 300~2000 g
Accuracy0.1g (0.1J)
Specimen ClampPneumatic Clamp
Pressure of Gas Supply0.6 MPa (outside of supply scope)
Port of Gas SupplyΦ8 mm PU Tubing
Specimen Size> 150 mm x 150 mm
Power SupplyAC 220V 50Hz

Additional Information:
  • Item Code: DIAMON-FDI-01
  • Pay Mode Terms: L/C (Letter of Credit),T/T (Bank Transfer),D/P,Other
  • Port of Dispatch: Ji'nan
  • Production Capacity: 10 unit per week
  • Delivery Time: 7 days after payment
  • Packaging Details: Veneer Case

Pendulum Impact Test Apparatus

Pendulum Impact Test Apparatus
Labthink provides film pendulum impact test Apparatus for plastic films, which conforms to ASTM D3420.

Technical Specifications
  • Impact Energy 1 J, 2 J, 3 J (Standard)
  • Resolution 0.001 J
  • Impact Head Size 25.4 mm, 19 mm, 12.7 mm (Customization is available)
  • Specimen Clamp Diameter 89 mm, 60 mm
  • Specimen Size 100 mm x 100 mm or 100 mm
  • Gas Supply Pressure 0.6 MPa (outside of supply scope)
  • Port Size 6 mm PU Tubing
  • Instrument Dimension 600 mm (L) x 390 mm (W) x 600 mm (H)

Additional Information:
  • Item Code: DIAMON-FIT-01

Falling Dart Impact Resistance Test Machine

Falling Dart Impact Resistance Test Machine
Labthink develops and manufacturers professional testing equipment for plastic packaging materials -- Impact Resistance test Machine by free falling dart method. 

Labthink Free falling dart impact Resistance test machine conforms to ASTM D1709 and has method A & Method B in one instrument. 

Labthink free Faling dart impact resistance Tester 
1. Manual and pedal swiches
2. observation light for convenient deserve 
3. Touch sreen 
4. Pneumatic clamping

Technical Specifications 
 Test Range Method A: 50~2000 g Method B: 300~2000 gAccuracy 0.1g (0.1J)Specimen Clamp Pneumatic ClampPressure of Gas Supply 0.6 MPa (outside of supply scope)Port of Gas Supply Φ8 mm PU TubingSpecimen Size > 150 mm x 150 mm

ASTM D3420 Film Pendulum Impact Testing Equipment

ASTM D3420 Film Pendulum Impact Testing Equipment
Labthink provides film pendulum impact testing equipment for plastic films, which conforms to ASTM D3420. 

Technical Specifications
  • Impact Energy 1 J, 2 J, 3 J (Standard)
  • Resolution 0.001 J
  • Impact Head Size 25.4 mm, 19 mm, 12.7 mm (Customization is available)
  • Specimen Clamp Diameter 89 mm, 60 mm
  • Specimen Size 100 mm x 100 mm or 100 mm
  • Gas Supply Pressure 0.6 MPa (outside of supply scope)
  • Port Size 6 mm PU Tubing
  • Instrument Dimension 600 mm (L) x 390 mm (W) x 600 mm (H)

Impact Resistance Test Machine

Impact Resistance Test Machine
FDI-01 Falling Dart Impact Resistance Test Machine is to measure impact resistance properties of Plastic Films, Foils, Sheeting, Paper and other packaging materials using free falling dart method. 

CHARACTERISTICS
  • Windows menu interface and touch screen
  • 2 test methods of A & B
  • Multi-unit result display
  • RS232 port and micro printer 


STANDARDS
The Falling Dart Impact Tester conforms to ASTM D1709

Technical Specifications 
Test Method Method A or Method B is optional
Test Range Method A: 50~2000 g Method B: 300~2000 g
Accuracy 0.1g (0.1J)
Specimen Clamp Pneumatic Clamp
Pressure of Gas Supply 0.6 MPa (outside of supply scope)
Port of Gas Supply Φ8 mm PU Tubing
Specimen Size > 150 mm x 150 mm
Power Supply AC 220V 50Hz
Net Weight 70 kg

Packaging Materials Films Pendulum Impact Testing Machines

Packaging Materials Films Pendulum Impact Testing Machines
FIT-01 Pendulum Impact Testing Machine can be used to determine impact resistance properties of pendulum of plastic films, sheets, composite films, aluminum foils and other materials in accordance with ASTM D3420.

FIT-01 Film Pendulum Impact Testing Machine is applicable to the determination of impact resistance of plastic films, sheets and composite films, paper and paper board

Pendulum Impact Testing Machine conforms to ASTM D3420

Technical Specifications
  1. Impact Energy: 1 J, 2 J, 3 J (Standard)
  2. Resolution: 0.001 J
  3. Impact Head Size: 25.4 mm, 19 mm, 12.7 mm (Customization is available)
  4. Specimen Clamp Diameter: 89 mm, 60 mm
  5. Specimen Size: 100 mm x 100 mm or 100 mm

Features
  • Adjustable range and electronic measurement support various combinations of non-standard test conditions
  • Pneumatic specimen clamping
  • automatic statistics of testing data for users’ convenient viewing

Related Products

FDI-01 Falling Dart Impact Testing Machine

Additional Information:
  • Item Code: PARAM-FIT-01
  • Pay Mode Terms: L/C (Letter of Credit),T/T (Bank Transfer)
  • Production Capacity: in s tock
  • Delivery Time: 7 days after payment
  • Packaging Details: Veneer Case

Pendulum Impact Testing Instrument

Pendulum Impact Testing Instrument
We are among the prominent manufacturers, suppliers, and exporters in the industry, offering Pendulum Impact Tester to our esteemed customers. Minimal effort is required in the operation of these testers as these devices can calculate the results automatically. Their range can be adjusted to facilitate the testing of various kinds of materials. Their high resolution LCD screen displays the results and related information clearly.

Features:

  • Digital design, microcomputer controls and calculates results automatically
  • Testing data collected fast
  • Accurate and reliable
  • Pneumatic clamps and pneumatic pendulum releasing
  • Results are more accurate
  • Perfect LCD can show the parameters,and results clearly
  • Micro computer works out the statistic data, build-in mini printer prints out the report
  • Adjustable range
  • Easy to operate

Specifications:

  • Impact energy: 1J, 2J, 3J
  • Resolution: 0.001J

Pendulum Impact Tester is applicable in film impact test of:

  • Plastic films
  • Foils
  • Laminated films
  • Aluminum foils

Pendulum Impact Tester is a necessary testing instrument for packaging corporations relating to:

  • Foodstuff
  • Pharmaceutical
  • Cosmetic as well as research center
  • Institute etc

Pendulum Impact Tester conforms to standards of:

  • ASTM D3420
  • NF T54-116

Additional Information:
  • Item Code: FIT-01

Plastic Packaging Free Falling Dart Impact Resistance Tester

Plastic Packaging Free Falling Dart Impact Resistance Tester
Labthink develops and manufacturers professional testing equipment for plastic packaging materials -- Impact resistance tester by free falling dart method. 

Labthink Free falling dart impact resistance tester conforms to ASTM D1709 and has method A & Method B in one instrument. 

Labthink free Faling dart impact resistance Tester
1. Manual and pedal swiches
2. observation light for convenient deserve
3. Touch sreen
4. Pneumatic clamping

Technical Specifications
 Test Range Method A: 50~2000 g Method B: 300~2000 gAccuracy 0.1g (0.1J)Specimen Clamp Pneumatic ClampPressure of Gas Supply 0.6 MPa (outside of supply scope)Port of Gas Supply Φ8 mm PU TubingSpecimen Size > 150 mm x 150 mm

Impact Testing Machine

Impact Testing Machine
Pendulum Impact Testing Machine
FIT-01 Pendulum Impact Resistance Tester is used to measure impact resistance of plastic film by pendulum method. 

FIT-01 Pendulum Impact Resistance Tester conforms to ASTM D3420

Pendulum Impact Resistance Tester is controlled by micro computer with LCD

Technical Specifications 
Impact Energy 1 J, 2 J, 3 J (Standard)Resolution 0.001 JImpact Head Size 25.4 mm, 19 mm, 12.7 mm (Customization is available)Specimen Clamp Diameter 89 mm, 60 mmSpecimen Size 100 mm x 100 mm or 100 mm 

Impact tester

Impact tester
Impact Tester
-- for flexible materials, films, sheeting
-- free falling impact tester ASTM D1709
-- Pendulum Impact Tester ASTM D3420

Labthink provides two methods of impact tester for flexible materials, such as films, foils, paper and other sheeting materials: Free Falling dart impact tester, conformed to ASTM D1709 and pendulum impact tester employing ASTM D3420 method.

FDI-01 Free Falling dart impact tester has two method (A&B) in one instrument. It is using Free Falling dart from a height method to measure impact resistance of plastic films.

FIT-01 Pendulum impact tester is professionally designed for plastic films with max load 3J.

For more information about labthink impact tester, please contact us.  

Material Impact Resistance Tester

Material Impact Resistance Tester
Technical Specifications
  1. Test Method Method A or Method B is optional
  2. Test Range Method A: 50~2000 g
  3. Method B: 300~2000 g
  4. Accuracy 0.1 g (0.1J)
  5. Specimen Clamp Pneumatic Clamp
  6. Pressure of Gas Supply 0.6 MPa (outside of supply scope)
  7. Port of Gas Supply Φ8 mm PU Tubing
  8. Specimen Size > 150 mm x 150 mm
  9. Power Supply AC 220V 50Hz
  10. Net Weight 70 kg

This Impact Resistance Tester conforms to various national and international standards:ASTM D1709, ISO 7765-1-1988, JIS K7124-1, GB/T 9639.1-2008


Additional Information:
  • Item Code: BMC

ASTM D3420 Pendulum Impact Test Machine

ASTM D3420 Pendulum Impact Test Machine
We are among the prominent manufacturers, suppliers, and exporters in the industry, offering Pendulum Impact Test Machine to our esteemed customers. Minimal effort is required in the operation of these testers as these devices can calculate the results automatically. Their range can be adjusted to facilitate the testing of various kinds of materials. Their high resolution LCD screen displays the results and related information clearly.

Features:

  • Digital design, microcomputer controls and calculates results automatically
  • Testing data collected fast
  • Accurate and reliable
  • Pneumatic clamps and pneumatic pendulum releasing
  • Results are more accurate
  • Perfect LCD can show the parameters,and results clearly
  • Micro computer works out the statistic data, build-in mini printer prints out the report
  • Adjustable range
  • Easy to operate

Specifications:

  • Impact energy: 1J, 2J, 3J
  • Resolution: 0.001J

Pendulum Impact Tester is applicable in film impact test of:

  • Plastic films
  • Foils
  • Laminated films
  • Aluminum foils

Pendulum Impact Tester is a necessary testing instrument for packaging corporations relating to:

  • Foodstuff
  • Pharmaceutical
  • Cosmetic as well as research center
  • Institute etc

Dart Impact Test Machine for Film

Dart Impact Test Machine for Film
Product Details:
  • Test Method: A & B

Labthink develops and manufacturers professional testing equipment for plastic packaging materials -- Impact Test Machine by free falling dart method.

Labthink Free falling dart impact test machine conforms to ASTM D1709 and has method A & Method B in one instrument.

Labthink free Faling dart impact test machine
1. Manual and pedal swiches
2. observation light for convenient deserve
3. Touch sreen
4. Pneumatic clamping

Technical Specifications
Test Range Method A: 50~2000 g Method B: 300~2000 gAccuracy 0.1g (0.1J)Specimen Clamp Pneumatic ClampPressure of Gas Supply 0.6 MPa (outside of supply scope)Port of Gas Supply Φ8 mm PU TubingSpecimen Size > 150 mm x 150 mm

Additional Information:
  • Pay Mode Terms: L/C (Letter of Credit),D/P,Other
  • Port of Dispatch: Ji'nan
  • Production Capacity: 10 unit per week
  • Delivery Time: 7 days after payment
  • Packaging Details: Veneer Case

Impact Resistance Test Apparatus

Impact Resistance Test Apparatus
Product Details:
  • Brand: Labthink
  • Model: FDI-01
  • Usage: Laboratory

Technical Specifications
  1. Test Method Method A or Method B is optional
  2. Test Range Method A: 50~2000 g
  3. Method B: 300~2000 g
  4. Accuracy 0.1 g (0.1J)
  5. Specimen Clamp Pneumatic Clamp
  6. Pressure of Gas Supply 0.6 MPa (outside of supply scope)
  7. Port of Gas Supply Φ8 mm PU Tubing
  8. Specimen Size > 150 mm x 150 mm
  9. Power Supply AC 220V 50Hz
  10. Net Weight 70 kg

This Impact Resistance Test Apparatus conforms to various national and international standards:ASTM D1709, ISO 7765-1-1988, JIS K7124-1, GB/T 9639.1-2008

This Impact Resistance Test Apparatus is based free falling dart or ball method for flexible materials, such as plastic films, Paper, Aluminum foils.

Impact Resistance Testing Equipment

Impact Resistance Testing Equipment
Impact test is to determine an object’s ability to resist high-rate impact. Impact resistance is one of the most important properties for a product designer. Basically, there are two kinds of testers for impact resistance test: free-falling dart impact tester and pendulum impact tester, conforming to different international standards.

BMC-B1 Falling Dart Impact resistance Testing Equipment
  • BMC-B1 is designed for determination of mechanical properties of packaging materials such as plastic films, laminates and paper by a free falling dart from a certain height. This instrument is designed according to ASTM D1709 with method A & B.


FDI-01 Falling Dart Impact Tester

  • FDI-01 can be used for the determination of impact resistance of packaging materials such as plastic films, laminates by a free falling dart from a certain height. This instrument is designed according to ASTM D1709 with method A & B.

FIT-01 Film Pendulum Impact Tester

  • FIT-01 can be used to determine impact resistance properties of pendulum of plastic films, sheets, composite films, aluminum foils and other materials in accordance with ASTM D3420.

Impact Resistance Testing Instrument

Impact Resistance Testing Instrument
Product Details:
  • Brand: Labthink
  • Model: FDI-01
  • Usage: Laboratory

Labthink develops and manufacturers professional testing equipment for plastic packaging materials -- Impact resistance testing Instrument by free falling dart method. 

Labthink Free falling dart impact resistance testing Instrument conforms to ASTM D1709 and has method A & Method B in one instrument. 

Labthink free Faling dart impact resistance Testing instrument 
1. Manual and pedal swiches
2. observation light for convenient deserve 
3. Touch sreen 
4. Pneumatic clamping

Technical Specifications 
 Test Range Method A: 50~2000 g Method B: 300~2000 gAccuracy 0.1g (0.1J)Specimen Clamp Pneumatic ClampPressure of Gas Supply 0.6 MPa (outside of supply scope)Port of Gas Supply Φ8 mm PU TubingSpecimen Size > 150 mm x 150 mm

Material Laboratory Equipments Dart Impact Tester

Material Laboratory Equipments Dart Impact Tester
Product Details:
  • Test Standard: ASTM D1709
  • Test Mehod: Free Falling Dart Method

Labthink Instruments is a professional manufaturer of material testing laboratory equipments. we focus on the solutions on your products.

 

Falling Dart Impact Tester (FDI-01), conform to ASTM D1709 with method A & B in one instrument

 

Tensile Tester, an universal material testing machine for tensile, peel, seal strength , puncture, tearing test

 

Ink Rub Tester(RT-01) ( Abrasion resistance Tester)

 

Tearing Tester(SLY-S1) based on Elmendorf method

 

for more pacakging testing instrument, please contact us


Additional Information:
  • Item Code: various
  • Pay Mode Terms: L/C (Letter of Credit),T/T (Bank Transfer),D/P,D/A
  • Delivery Time: 7 days after payment
  • Packaging Details: Veneer Case

Pendulum Impact Resistance Test Machine

Pendulum Impact Resistance Test Machine
FIT-01 Pendulum Impact Resistance Test Machine is used to measure impact resistance of plastic film by pendulum method. 

FIT-01 Pendulum Impact Resistance Tester conforms to ASTM D3420

Pendulum Impact Resistance Tester is controlled by micro computer with LCD

Technical Specifications 
Impact Energy 1 J, 2 J, 3 J (Standard)Resolution 0.001 JImpact Head Size 25.4 mm, 19 mm, 12.7 mm (Customization is available)Specimen Clamp Diameter 89 mm, 60 mmSpecimen Size 100 mm x 100 mm or 100 mm 

Free Falling Ball Impact Tester

Free Falling Ball Impact Tester
Impact test is to determine an object’s ability to resist high-rate impact. Impact resistance is one of the most important properties for a product designer. Basically, there are two kinds of testers for impact resistance test: free-falling dart impact tester and pendulum impact tester, conforming to different international standards.

BMC-B1 Falling Dart Impact Tester
  • BMC-B1 is designed for determination of mechanical properties of packaging materials such as plastic films, laminates and paper by a free falling dart from a certain height. This instrument is designed according to ASTM D1709 with method A & B.


FDI-01 Falling Dart Impact Tester

  • FDI-01 can be used for the determination of impact resistance of packaging materials such as plastic films, laminates by a free falling dart from a certain height. This instrument is designed according to ASTM D1709 with method A & B.

FIT-01 Film Pendulum Impact Tester

  • FIT-01 can be used to determine impact resistance properties of pendulum of plastic films, sheets, composite films, aluminum foils and other materials in accordance with ASTM D3420.

 

 


Additional Information:
  • Item Code: impact
  • Pay Mode Terms: L/C (Letter of Credit),T/T (Bank Transfer)

Drop Dart Impact Tester ASTM D1709

Drop Dart Impact Tester ASTM D1709
FDI-01 Drop Dart Impact Tester can be used for the determination of impact resistance of packaging materials such as plastic films, laminates by a free falling dart from a certain height. This instrument is designed according to ASTM D1709 with method A & B.

This Drop Dart Impact Tester conforms to ASTM D1709

Applications
Drop dart Impact Tester is applicable impact resistance test of Plastic films, aluminum foils and aluminum plastic composite films, Paper and Paperboard

Features
  • Pneumatic clamping
  • manual and pedal switch
  • built-in observation light
  • professional software
  • RS232

Technical Specifications
  1. Test Method: Method A or Method B is optional
  2. Test Range: Method A: 50~2000 g
  3. Method B: 300~2000 g
  4. Accuracy: 0.1g (0.1J)
  5. Specimen Clamp: Pneumatic Clamp
  6. Pressure of Gas Supply: 0.6 MPa (outside of supply scope)
  7. Port of Gas Supply: Φ8 mm PU Tubing
  8. Specimen Size: > 150 mm x 150 mm

Additional Information:
  • Item Code: FDI-01
  • Pay Mode Terms: L/C (Letter of Credit),T/T (Bank Transfer)
  • Production Capacity: in Stock
  • Delivery Time: 7 days after payment
  • Packaging Details: Veneer Case

Pendulum Impact Tester

Pendulum Impact Tester
We are among the prominent manufacturers, suppliers, and exporters in the industry, offering Pendulum Impact Tester to our esteemed customers. Minimal effort is required in the operation of these testers as these devices can calculate the results automatically. Their range can be adjusted to facilitate the testing of various kinds of materials. Their high resolution LCD screen displays the results and related information clearly.

Features:

  • Digital design, microcomputer controls and calculates results automatically
  • Testing data collected fast
  • Accurate and reliable
  • Pneumatic clamps and pneumatic pendulum releasing
  • Results are more accurate
  • Perfect LCD can show the parameters,and results clearly
  • Micro computer works out the statistic data, build-in mini printer prints out the report
  • Adjustable range
  • Easy to operate

Specifications:

  • Impact energy: 1J, 2J, 3J
  • Resolution: 0.001J

Pendulum Impact Tester is applicable in film impact test of:

  • Plastic films
  • Foils
  • Laminated films
  • Aluminum foils

Pendulum Impact Tester is a necessary testing instrument for packaging corporations relating to:

  • Foodstuff
  • Pharmaceutical
  • Cosmetic as well as research center
  • Institute etc

Pendulum Impact Resistance Tester

Pendulum Impact Resistance Tester
FIT-01 Pendulum Impact Resistance Tester is used to measure impact resistance of plastic film by pendulum method. 

FIT-01 Pendulum Impact Resistance Tester conforms to ASTM D3420

Pendulum Impact Resistance Tester is controlled by micro computer with LCD

Technical Specifications
Impact Energy 1 J, 2 J, 3 J (Standard)Resolution 0.001 JImpact Head Size 25.4 mm, 19 mm, 12.7 mm (Customization is available)Specimen Clamp Diameter 89 mm, 60 mmSpecimen Size 100 mm x 100 mm or 100 mm 

Falling Dart Impact Test Machine

Falling Dart Impact Test Machine
Labthink develops and manufacturers professional testing equipment for plastic packaging materials -- Impact test Machine by free falling dart method. 

Labthink Free falling dart impact impact test machine conforms to ASTM D1709 and has method A & Method B in one instrument. 

Labthink free Faling dart impact resistance Tester 
1. Manual and pedal swiches
2. observation light for convenient deserve 
3. Touch sreen 
4. Pneumatic clamping

Technical Specifications 
 Test Range Method A: 50~2000 g Method B: 300~2000 gAccuracy 0.1g (0.1J)Specimen Clamp Pneumatic ClampPressure of Gas Supply 0.6 MPa (outside of supply scope)Port of Gas Supply Φ8 mm PU TubingSpecimen Size > 150 mm x 150 mm

Drop Ball Impact Tester

Drop Ball Impact Tester
FDI-01 Drop Ball Impact Tester is to measure impact resistance properties of Plastic Films, Foils, Sheeting, Paper and other packaging materials using free falling dart method.

CHARACTERISTICS
  • Windows menu interface and touch screen
  • 2 test methods of A & B
  • Multi-unit result display
  • RS232 port and micro printer


STANDARDS
The Drop Ball Impact Tester conforms to ASTM D1709

Technical Specifications
Test Method Method A or Method B is optional
Test Range Method A: 50~2000 g Method B: 300~2000 g
Accuracy 0.1g (0.1J)
Specimen Clamp Pneumatic Clamp
Pressure of Gas Supply 0.6 MPa (outside of supply scope)
Port of Gas Supply Φ8 mm PU Tubing
Specimen Size > 150 mm x 150 mm
Power Supply AC 220V 50Hz
Net Weight 70 kg

Additional Information:
  • Pay Mode Terms: L/C (Letter of Credit),T/T (Bank Transfer),D/P,Other
  • Port of Dispatch: Ji'nan
  • Production Capacity: 10 unit per week
  • Delivery Time: 7 days after payment
  • Packaging Details: Veneer Case

Drop Ball Impact Test Machine

Drop Ball Impact Test Machine
FDI-01 Drop Ball Impact Test Machine is to measure impact resistance properties of Plastic Films, Foils, Sheeting, Paper and other packaging materials using free falling dart method. 

CHARACTERISTICS
  • Windows menu interface and touch screen
  • 2 test methods of A & B
  • Multi-unit result display
  • RS232 port and micro printer 


STANDARDS
The Drop Ball Impact Test Machine conforms to ASTM D1709

Technical Specifications 
Test Method Method A or Method B is optional
Test Range Method A: 50~2000 g Method B: 300~2000 g
Accuracy 0.1g (0.1J)
Specimen Clamp Pneumatic Clamp
Pressure of Gas Supply 0.6 MPa (outside of supply scope)
Port of Gas Supply Φ8 mm PU Tubing
Specimen Size > 150 mm x 150 mm
Power Supply AC 220V 50Hz
Net Weight 70 kg

Falling Dart Impact Test Equipment

Falling Dart Impact Test Equipment
We are among the leading names in the industry, offering Falling Dart Impact Tester to our revered customers. Characterized by pneumatic clamping and pneumatic pendulum releasing systems, these testers provide accurate results. Statistical data can be speedily obtained owing to the mini-computer and the inbuilt printer. Packaging materials pertaining to food, pharmaceutical, and cosmetic products can be subjected to these testers.

Features:

  • Digital design, microcomputer controls and calculates results automatically
  • Testing data collected fast
  • Pneumatic clamps
  • Perfect LCD can show the parameters
  • Micro computer works out the statistic data
  • Build-in mini printer prints out the report
  • Adjustable range
  • Easy to operate

Specifications:

  • Test Range: method A: 50~2,000g
  • Method B: 300~2,000g
  • Accuracy: 0.1g (0.1J)

Falling Dart Impact Tester is a necessary testing instrument for:

  • Packaging corporations relating to foodstuff
  • Pharmaceutical
  • Cosmetic
  • As well as research center & Institute

Falling Dart Impact Tester conforms to standards of:


  • ASTM D1709
  • ISO 7765

Additional Information:
  • Item Code: BMC-B1

Pendulum Impact Test Stand

Pendulum Impact Test Stand
Labthink provides film pendulum impact test stand for plastic films, which conforms to ASTM D3420. 

Technical Specifications 
  • Impact Energy 1 J, 2 J, 3 J (Standard)
  • Resolution 0.001 J
  • Impact Head Size 25.4 mm, 19 mm, 12.7 mm (Customization is available)
  • Specimen Clamp Diameter 89 mm, 60 mm
  • Specimen Size 100 mm x 100 mm or 100 mm
  • Gas Supply Pressure 0.6 MPa (outside of supply scope)
  • Port Size 6 mm PU Tubing
  • Instrument Dimension 600 mm (L) x 390 mm (W) x 600 mm (H)
X
Provide Us More Details
Is this Requirement:

One Time Regular

How soon do you want this:

Immediate After 1 month

Purpose of Requirement:

Reselling End Use Raw Material

X